Product Number: 43906LW

LIGHTNING CONTROL DMX512 LSZH

LIGHTNING CONTROL 2 PAIR 22AWG/0.34mm² DMX512 FRNC LSZH

  • Availability:
    Global
  • Global inventory:
    Available
43906LW
  • Specifications
  • Resources

Specifications

Suitable Applications

DMX 512 lighting control applications

Conductor

AWG Stranding Material Construction n x D
22 7x30 TC - Tinned Copper 7x0.25 mm

Conductor Count

4

Total Number of Pairs

2

Insulation

Type Material Nominal Diameter Diameter +/- Tolerance
Insulation PE - Polyethylene 1.35 mm 0.10 mm

Color Chart

Number Color
Pair 1 White & Red
Pair 2 Green & Black

Outer Shield

Type Material Coverage [%] Thickness of Foil Drainwire Material Drainwire AWG Drainwire Construction n x D Drainwire Position
Braid Tinned Copper (TC) 80% TC - Tinned Copper 24 7x0.20 mm Over foil, under braid
Tape Bi-Laminate (Alum+Poly) 100% 9/23 µm

Outer Jacket

Nominal Diameter Diameter +/- Tolerance
7.50 mm 0.25 mm

Table Notes

Matte Finish Sheath

Cabling

Description
2 pairs twisted

Conductor DCR

Max. Conductor DCR Max. Outer Shield DCR
58 Ohm/km 15 Ohm/km

Capacitance

Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
70 pF/m 112 pF/m

Inductance

Nominal Inductance
0.68 µH/m

Storage Temperature Range

-25°C To +70°C

Other Temp Range

-5 to +70 °C

Bulk Cable Weight

61 kg/km

CPR Euroclass

Cca-s1,d1,a1

Environmental Space

Indoor - Euroclass Cca

EU Directive 2011/65/EU (RoHS 2)

Yes

IEC Flammability

IEC 60332-1-2

IEC 60754-1 - Halogen Amount

Zero

IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity

2.5 µS/mm

IEC 60754-2 - Halogen Acid Gas Amount - Min. pH

4.3

IEC 61034-2 - Smoke Density Min. Transmittance

60%

Update and Revision

Revision Number: 0.16 Revision Date: 08-31-2022