DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, CPE Jkt, CMG, CL2
Suitable Applications |
harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc. |
---|
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Power Pair(s) | 1 | 22 AWG | 19x34 | TC - Tinned Copper |
Data Pair(s) | 1 | 24 AWG | 19x36 | TC - Tinned Copper |
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Power Pair(s) | PVC - Polyvinyl Chloride | 0.021 in (0.53 mm) | 0.072 in (1.8 mm) | Red & Black |
Data Pair(s) | PE - Polyethylene (Foam) | 0.026 in (0.66 mm) | 0.077 in (2.0 mm) | Blue & White |
Element | Shield Type | Material | Coverage |
---|---|---|---|
Power Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% |
Data Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% |
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Braid | Tinned Copper (TC) | 65% | 22 AWG (19x34) TC |
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
CPE - Chlorinated Polyethylene | 0.033 in (0.84 mm) | 0.280 in (7.11 mm) |
Table Notes |
Jacket OD +/- 0.005 |
---|---|
Overall Cable Diameter (Nominal) |
0.280 in (7.11 mm) |
Element | Nom. Conductor DCR | Max. Conductor DCR | Nom. Inner Shield DCR | Nom. Capacitance Cond-to-Cond | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|---|---|---|---|---|---|---|
Power Pair(s) | 18.2 Ohm/1000ft | 17.5 Ohm/1000ft | 7.95 Ohm/1000ft (26.1 Ohm/km) | 6 Amps per Conductor at 30ºC | |||
Data Pair(s) | 28.8 Ohm/1000ft (94.5 Ohm/km) | 28 Ohm/100m | 7.45 Ohm/1000ft (24.4 Ohm/km) | 12.0 pF/ft (39.4 pF/m) | 120 Ohm | 75% | 6 Amps per Conductor at 30ºC |
Nom. Outer Shield DCR |
5 Ohm/1000ft (16 Ohm/km) |
---|
Element | Frequency [MHz] | Max. Insertion Loss (Attenuation) |
---|---|---|
Data Pair(s) | 0.125 | .29 dB/100ft |
0.5 | 0.5 dB/100ft | |
1 | 0.7 dB/100ft |
UL Voltage Rating |
---|
300 V (CMG, CL2) |
UL Temperature | Operating |
---|---|
75°C | -20°C to +75°C |
Stationary Min. | Installation Min. |
---|---|
2.8 in (71 mm) | 2.8 in (71 mm) |
Max. Pull Tension |
70.06 lbs (31.78 kg) |
---|---|
Bulk Cable Weight |
46 lbs/1000ft |
Environmental Suitability |
Indoor, Outdoor, Sunlight Resistance |
---|---|
Flammability / Reaction to Fire |
UL 1685 FT4 Loading, IEEE 1202 FT4, IEC 60332-1-2 |
CPR Compliance |
CPR Euroclass: Eca |
NEC / UL Compliance |
Article 725, Article 800, CL2, CMG |
CEC / C(UL) Compliance |
CMG |
European Directive Compliance |
EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance |
UKCA Mark |
APAC Compliance |
China RoHS II (GB/T 26572-2011) |
Other Standard Compliance(s) |
ODVA Class 2 Thin |
Notes |
Thin. Meter marks on jacket to aid users in installation. ODVA Devicenet is an Open DeviceNet Vendor Association, Inc. trademark. |
---|
Update and Revision |
Revision Number: 0.552 Revision Date: 04-30-2024 |
---|
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
3085A 5601000 | Yellow, Bright | Reel | 1,000 ft | 612825140993 | C |
3085A 5602000 | Yellow, Bright | Reel | 2,000 ft | 612825141006 | C |
3085A 5605000 | Yellow, Bright | Reel | 5,000 ft | 612825141020 | C Z |