8762ELW

Electronic, 2 C #20 Str TC, PE ins, OS, LSNH Jkt, 300V, Cca

...
Electronic, 2 Conductor 20AWG (7x28) Tinned Copper, PE Insulation, Overall Beldfoil® Shield, LSZH Outer Jacket, Cca
Request Sample Get Product Alerts

Specifications
Product Overview

Suitable Applications

Instrumentation and computer cable; For data transmission applications

Physical Characteristics (Overall)
Conductor
AWG Stranding Material No. of Pairs
20 7x28 TC - Tinned Copper 1

Conductor Count

2

Insulation
Material Nominal Diameter Diameter +/- Tolerance Nominal Wall Thickness
PE - Polyethylene 1.78 mm 0.05 mm 0.016 in
Color Chart
Number Color
Pair 1 Black & Clear
Outer Shield
Type Material Material Trade Name Coverage [%] Thickness of Foil Drainwire Material Drainwire AWG Drainwire Construction n x D
Tape Bi-Laminate (Alum+Poly) Beldfoil® (Z-Fold®) 100% 9 / 12 µm TC - Tinned Copper AWG20/7 7x28
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
LSZH - Low Smoke Zero Halogen (Flame Retardant) 5.4 mm 0.9 mm
Construction and Dimensions
Stranding
Twists
6 twist/ft
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR
31.2 Ohm/km
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
88.6 pF/m 160.8 pF/m
Inductance
Nominal Inductance Nominal Pair Inductance
0.18 µH/ft 0.591 µH/m
Impedance
Nominal Characteristic Impedance
56 Ohm
Delay
Nominal Velocity of Propagation (VP) [%]
66%
Current
Element Max. Recommended Current [A]
Conductor(s) 3.9 Amps per Conductor
Voltage
Voltage Rating [V]
300 V
Temperature Range

Installation Temperature Range

-15°C To +80°C

Storage Temperature Range

-45°C To +80°C

Operating Temp Range (Flexible Install)

-15°C To +80°C

Operating Temp Range (Fixed Install)

-45°C To +80°C

Mechanical Characteristics

Oil Resistance

IEC 60811-404

Max. Pull Tension

210 N

Min. Bend Radius During Installation

54 mm

Min. Bend Radius/Minor Axis

2 in

Standards

CPR Euroclass

Cca-s1,d1,a1

CENELEC Compliance

EN 50290-2-20

Applicable Environmental and Other Programs

Environmental Space

Indoor/Outdoor - Euroclass Cca

EU Directive Compliance

EU Directive 2003/11/EC (BFR)

EU CE Mark

Yes

MII Order #39 (China RoHS)

Yes

Suitability

Suitability - Indoor

Yes

Suitability - Non-Halogenated

Yes

Suitability - Sunlight Resistance

Yes

Flammability, LS0H, Toxicity Testing

IEC Flammability

IEC 60332-1-2

IEC 60754-1 - Halogen Amount

Zero

IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity

2.5 µS/mm

IEC 60754-2 - Halogen Acid Gas Amount - Min. pH

4.3

IEC 61034-2 - Smoke Density Min. Transmittance

60%

Plenum/Non-Plenum

Plenum (Y/N)

No

History

Update and Revision

Revision Number: 0.38 Revision Date: 06-28-2024

Part Numbers
Item #
8762ELW.00305