Composite ENG, EFP and CCTV
Element | AWG | Stranding | Material | Nominal Diameter | No. of Pairs | No. of Coax |
---|---|---|---|---|---|---|
Coax(es) | 22 | Stranded | BC - Bare Copper | 0.03 in | 1 | |
Pair(s) | 22 | 7x30 | TC - Tinned Copper | 0.03 in | 1 |
Total Number of Pairs |
1 |
---|
Element | Material | Nominal Diameter |
---|---|---|
Coax(es) | PE - Polyethylene (Foam) | 0.146 in |
Pair(s) | PVC - Polyvinyl Chloride | 0.054 in |
Number | Color |
---|---|
1 | Black |
2 | Red |
Element | Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
---|---|---|---|---|---|---|---|---|
Coax(es) | Braid | Bare Copper (BC) | 95% | TC - Tinned Copper | 0.03 in | 22 | 7x30 | |
Pair(s) | Tape | Bi-Laminate (Alum+Poly) | Beldfoil® (Z-Fold®) | 100% |
Material | Nominal Diameter |
---|---|
PVC - Polyvinyl Chloride | 0.47 in |
Nominal Conductor DCR Conductor Resistance | Nominal Inner Shield DCR | Nominal Outer Shield DCR |
---|---|---|
15 Ohm/1000ft | 2.6 Ohm/1000ft | 11 Ohm/1000ft |
Element | Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Shield |
---|---|---|
Coax(es) | 51 pF/ft | 17.3 pF/ft |
Pair(s) | 95.5 pF/ft |
Nominal Inductance |
---|
0.09 µH/ft |
Element | Nominal Characteristic Impedance |
---|---|
Coax(es) | 75 Ohm |
Element | Frequency [MHz] | Nom. Insertion Loss |
---|---|---|
Coax(es) | 1 MHz | 0.3 dB/100ft |
5 MHz | 0.7 dB/100ft | |
10 MHz | 1 dB/100ft | |
50 MHz | 2.1 dB/100ft | |
100 MHz | 3 dB/100ft |
Element | Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|---|---|
Coax(es) | 1.3 ns/ft | 78% |
UL Voltage Rating |
---|
30 V RMS |
Electrical Characteristics Notes |
Coax Nominal Voltage Breakdown Jacket (Shield to Ground) = 22kV RMS |
---|
Non-UL Temp Rating |
60°C |
---|---|
Operating Temperature Range |
-40°C To +60°C |
Bulk Cable Weight |
58 lbs/1000ft |
---|---|
Max. Pull Tension |
68 lbs |
Min. Bend Radius/Minor Axis |
2.5 in |
NEC/(UL) Compliance |
CL2 |
---|---|
UL AWM Style Compliance |
AWM 20006 |
CPR Euroclass |
Eca |
RG Type |
59 |
Environmental Space |
Indoor (Not Riser or Plenum) |
---|---|
EU Directive 2000/53/EC (ELV) |
Yes |
EU Directive 2003/11/EC (BFR) |
Yes |
EU Directive 2011/65/EU (RoHS 2) |
Yes |
EU Directive 2012/19/EU (WEEE) |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment) |
Yes |
EU Directive Compliance |
Yes |
EU CE Mark |
No |
MII Order #39 (China RoHS) |
Yes |
Suitability - Indoor |
Yes |
---|
UL Flammability |
UL1685 UL Loading |
---|---|
UL voltage rating |
30 V RMS |
Plenum (Y/N) |
No |
---|
Footnote |
C - CRATE REEL PUT-UP. |
---|
Notes |
Simaese Type Construction. |
---|
Update and Revision |
Revision Number: 0.356 Revision Date: 04-29-2024 |
---|
Item # | Color | Put-Up Type | Length | UPC |
---|---|---|---|---|
9265 010500 | Black | Reel | 500 ft | 612825226017 |
9265 0101000 | Black | Reel | 1,000 ft | 612825226000 |