DeviceBus®, 2 Pr #16+18 Str TC, PVC-NYL+PP Ins, IS+OA TC Brd, PVC Jkt, 600V TC-ER
Suitable Applications |
harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc. |
---|
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Power Pair(s) | 1 | 16 AWG | 19x29 | TC - Tinned Copper |
Data Pair(s) | 1 | 18 AWG | 19x30 | TC - Tinned Copper |
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|---|---|---|---|---|
Power Pair(s) | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.022 in (0.56 mm) | 0.101 in (2.57 mm) | Red & Black | |
Data Pair(s) | PP - Polypropylene | 0.033 in (0.84 mm) | 0.182 in (4.62 mm) | Blue & White | Flame Retardant |
Element | Shield Type | Material | Coverage |
---|---|---|---|
Power Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% |
Data Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% |
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Braid | Tinned Copper (TC) | 70% | 16 AWG (19x29) TC |
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC - Polyvinyl Chloride | 0.060 in (1.5 mm) | 0.525 in (13.3 mm) |
Table Notes |
Jacket OD +/- 0.010 |
---|---|
Overall Cable Diameter (Nominal) |
0.525 in (13.3 mm) |
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|---|---|---|---|---|
Power Pair(s) | 4.9 Ohm/1000ft | 8 Amps per Conductor at 25ºC | |||
Data Pair(s) | 6.9 Ohm/1000ft (23 Ohm/km) | 14.7 pF/ft (48.2 pF/m) | 120 Ohm | 75% |
Nom. Outer Shield DCR |
1.8 Ohm/1000ft (5.9 Ohm/km) |
---|
Element | Frequency [MHz] | Max. Insertion Loss (Attenuation) | Max./Min. Input Impedance (unFitted) [Ohm] |
---|---|---|---|
Data Pair(s) | 0.125 | 0.13 dB/100ft | 120 |
0.5 | 0.25 dB/100ft | ||
1 | 0.40 dB/100ft |
UL Voltage Rating |
---|
600 V (TC-ER) |
UL Temperature | Operating | Installation |
---|---|---|
75°C Dry | -40°C to +75°C | -25°C To +75°C |
Stationary Min. | Installation Min. |
---|---|
5 in (130 mm) | 5 in (130 mm) |
Max. Pull Tension |
190 lbs (86 kg) |
---|---|
Bulk Cable Weight |
158 lbs/1000ft |
Environmental Suitability |
Indoor, Outdoor, Sunlight Resistance, Oil Resistance |
---|---|
Flammability / Reaction to Fire |
UL 1685 UL Loading, FT1 |
CPR Compliance |
CPR Euroclass: Eca |
NEC / UL Compliance |
Article 336, TC-ER |
AWM Compliance |
AWM I/II A/B |
European Directive Compliance |
EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance |
UKCA Mark |
APAC Compliance |
China RoHS II (GB/T 26572-2011) |
Other Standard Compliance(s) |
ODVA Cable V |
Notes |
Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark. |
---|
Update and Revision |
Revision Number: 0.592 Revision Date: 04-30-2024 |
---|
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
7896A T5U500 | Gray T5U | Reel | 500 ft | 612825190844 | C |
7896A T5U1000 | Gray T5U | Reel | 1,000 ft | 612825190820 | C |
7896A T5U2000 | Gray T5U | Reel | 2,000 ft | 612825190837 | C |