Product Number: H1000C2

H1000C2 - 50 Ohm Wireless Radiating Coax, H1000, RG8, 10 AWG Solid BC, 25% BC Braid, PVC Jkt

50 Ohm Wireless Radiating Coax, H1000, RG8, 10 AWG Solid Bare Copper Conductor, PE Insulation, 25% Bare Copper Braid Shield, PVC Jacket

  • Availability:
    EMEA | Asia Pacific
  • Global inventory:
    Available
  • Specifications
  • Resources

Specifications

Suitable Applications

Point-to-point and point-to-multipoint wireless antenna communication; Wireless microphones, Two-Way Radios, Amateur (Ham) Radio, Low Power FM, GPS, RFID (Radio Frequency Identification)

RG Type

8

Conductor

No. of Elements Size Stranding Nom. Diameter Material
1 10 AWG Solid 2.62 mm BC - Bare Copper

Insulation

Material Nom. Insulation Diameter
PE - Polyethylene (Foam) 7.15 mm (0.281 in)

Table Notes

Centricity min. 85%

Outer Shield

Outer Shield Type Material Coverage
Braid Bare Copper (BC) 25%

Outer Jacket

Material Nom. Diameter
PVC - Polyvinyl Chloride 10.3 mm

Table Notes

According to European Standard EN 50290-2-20

Regularity of Impedance

Min. 46 dB

Attenuation

Frequency Nom. Attenuation
10 MHz 2 dB/100m
50 MHz 4.5 dB/100m
100 MHz 6.3 dB/100m
230 MHz 9.6 dB/100m
300 MHz 11.4 dB/100m
400 MHz 13 dB/100m
860 MHz 19.4 dB/100m
1000 MHz 22.5 dB/100m

Table Notes

Max. attenuation 10% higher

Electricals

Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Shield Nom. Characteristic Impedance Nom. Velocity of Prop.
3.5 Ohm/km (1.1 Ohm/1000ft) 35 Ohm/km (11 Ohm/1000ft) 80 pF/m (24 pF/ft) 50 Ohm 83%

Temperature

Operating Installation Storage
-40°C To +70°C -5°C To +50°C -40°C To +70°C

Bend Radius

Stationary Min.
100 mm (3.9 in)

Bulk Cable Weight

119 kg/km

Environmental Suitability

Indoor/Outdoor

ISO/IEC Compliance

IEC 61196

Update and Revision

Revision Number: 0.195 Revision Date: 04-29-2024

Update and Revision

Revision Number: 0.195 Revision Date: 04-29-2024