Product Number: BPB52L1F

CAT5 100Ω 4x22AWG Profinet Type B fire resistant cable

CAT5 100Ω 4x22AWG Profinet Type B fire resistant cable, IEC 60332-23, EN 50200, EN50289-4-16, 80C, 300V, ROHS

  • Availability:
    Global
  • Global inventory:
    Available
  • Specifications
  • Resources

Specifications

Suitable Applications

For railway Ethernet Networking, Fire resistance, ProfiNet Application

Conductor

Size Material
22 AWG TC - Tinned Copper

Insulation

Material Nom. Insulation Diameter Color Code
PO - Polyolefin 1.4 mm (0.055 in) White, Yellow, Blue, Orange

Table Notes

Fire resistance tape wrapped over insulated cores

Outer Shield

Shield Type Material Coverage Notes
Tape Polyester + Bi-Laminate (Alum+Poly)
Braid Tinned Copper (TC) 80% Fire resistance tape wrapped over braid

Outer Jacket

Material
LSZH - Low Smoke Zero Halogen (Flame Retardant)

Table Notes

E-beam cross-linked LSZH

Overall Cable Diameter (Nominal)

7.3 mm (0.29 in)

Electricals

Max. Conductor DCR
59.4 Ω/km

Table Notes

Nom. fitted Impedance (Ω) 100 & Nom. Mutual Capacitance 56 pF/m

High Frequency

Frequency Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. RL (Return Loss) [dB] Min. Coupling Attenuation [dB]
4 4.9 dB/100 m 53 23
8 MHz 6.9 dB/100 m 48.5 24.5
10 MHz 7.8 dB/100 m 47 25
16 MHz 9.9 dB/100 m 43.9 25
20 MHz 11.1 dB/100 m 42.5 25
25 MHz 12.5 dB/100 m 41 24.2
31.3 MHz 14.1 dB/100 m 39.6 23.3 80
40 MHz 16.1 dB/100 38 22.4 80
62.5 MHz 20.4 dB/100 m 35.1 20.7 80
100 MHz 26.4 dB/100 m 32 19 80

Voltage

Voltage Rating Breakdown Voltage
300 V 2 kVac/min

Temperature

Operating
-40 ℃ to + 80℃

Table Notes

Nom. Bulk Weight of cable 70 kg/km

Flammability / Reaction to Fire

IEC 60332-1-2, IEC 60332-3-25, IEC 60331-23, BS EN 50200 PH120

ISO/IEC Compliance

IEC 61156-2, IEC 61034-2 - Smoke Density Min Transmittance = 70%

CENELEC Compliance

EN 50289

European Halogen Free Standards

IEC 60754-1 - Halogen Amount = 0.5%, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 , IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3

European Directive Compliance

EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2)

APAC Compliance

China RoHS II (GB/T 26572-2011)

Other Standard Compliance(s)

TJ/CL 313

Notes

Toxicity of insulation (EN 45545-2 Table 5-R15 and R16-HL3) ≦ 6 ; Toxicity of jacket (EN 45545-2 Table 5-R15 and R16-HL3) ≦ 6 ; Hazard level (EN 45545-2) HL3 ; IEC 61156-6, UL 758

Update and Revision

Revision Number: 0.21 Revision Date: 07-05-2024

Update and Revision

Revision Number: 0.21 Revision Date: 07-05-2024