UTG10RVFU

UTG 10 REVConnect FlexPlug, UTP, Single Pack

UTG10RVFU
UTG 10 REVConnect FlexPlug, UTP, Single Pack
Get Product Alerts

Specifications
Product Overview

Suitable Applications

UTG 10, 1GBASE-T

Physical Characteristics (Overall)
Conductor
AWG Stranding Material No. of Pairs
23 Solid BC - Bare Copper 4
Insulation
Material
PO - Polyolefin
Outer Jacket
Material
PVC - Polyvinyl Chloride

Overall Nominal Diameter

0.23 in.

Wiring Scheme

T568A/B-T568A/B

Packaging

Individually packaged in a clear plastic bag.

Weight

0.060 lbs

Connectors
Materials
Description Material Type
Cable End 1, Plug Polycarbonate RJ45
Cable End 1, Connection Phosphor Bronze with 50u inch Gold over Nickel Plating RJ45 Blades
Cable End 2, Connection 50uin Gold plated contacts REVConnect
Electrical Characteristics

Dielectric Strength

1,000 V RMS @ 60 Hz

Current Rating

1.500 A

Insulation Resistance

500 M-Ohm Minimum

Max Contact Resistance

20 mOhm

High Frequency
Frequency [MHz] Min. NEXT [dB] Min. RL (Return Loss) [dB]
1 MHz 65 dB 19.8 dB
4 MHz 65 dB 21.6 dB
8 MHz 65 dB 22.5 dB
10 MHz 65 dB 22.8 dB
16 MHz 62.6 dB 23.4 dB
20 MHz 60.7 dB 23.7 dB
25 MHz 58.8 dB 24 dB
31.25 MHz 56.9 dB 23 dB
62.5 MHz 51 dB 20 dB
100 MHz 47 dB 18 dB
200 MHz 41.1 dB 15 dB
250 MHz 39.3 dB 14 dB
300 MHz 37 dB 12.8 dB
400 MHz 33.6 dB 10.9 dB
500 MHz 31 dB 9.5 dB
625 MHz 28.3 dB 8 dB
Temperature Range

Installation Temperature Range

-10°C To +60°C

Storage Temperature Range

-40°C To +70°C

Operating Temperature Range

-10°C To +60°C

Mechanical Characteristics

Min Bend Radius (Overall Cable)

1.040 in.

Plug /Jack Compatibility

RJ45, REVConnect Core

Termination Interface
Termination Connection Durabilities
Cable End 1 - RJ45 Mated Connection 750 Cycles
Cable End 2 - RevConnect Mated Connection 20 Cycles
Standards

UL Rating

UL94 V-0, UL1863, UL2043

IEEE Compliance

Power Over Ethernet (PoE) IEEE 802.3at type 1 and 2 (up to 30W), IEEE802.3bt/D1.7 type 3 and 4 (up to 100W), CISCO UPOE (up to 60W), Power over HDBaseTTM (up to 100W)

Other Standards

IEC 60603-7, FCC Part 68, Subpart F

Third Party Performance Verification

UTG Framework 1.0

Applicable Environmental and Other Programs

Environmental Space

Indoor

EU Directive 2002/95/EC (RoHS)

Yes

MII Order #39 (China RoHS)

EUP 50

Suitability

Suitability - Indoor

Yes

Flammability, LS0H, Toxicity Testing

Safety Listing

c(UL)us Listed

History

Update and Revision

Revision Number: 0.8 Revision Date: 07-10-2019

Resources
Warranties